Imagen
DF-Series Pneumatic Automatic Reusable Barb Coupler
Imagen
d-ru 3d half

2DL3-B - Serie - DF Cople Intercambio Industrial (Conexión Reutilizable para Manguera)

Dixon Distributor? 

Log in to view pricing, inventory, place orders & much more. If you want to create an account, please click the button to begin the registration process.

Atributos

Peso
0.39 lb
Break Quantity
0
Paquete Opcional/Cantidad por Caja
0
Material
Latón
DE Máximo
0.98"
Tamaño de Cuerpo
1/4"
Rango de Temperatura
-40°F to 250°F (-40°C to 121°C)
Longitud
2.85"
DI de Manguera
3/8"
Hex
11/16"
DE de Manguera
3/4"
Valor de Presión
See Product Details

Detalles

Compatibility & Interchange Data

  • Foster 3, 4, 5 and 6 Series
  • Parker 30 - Series Automatic Interchange
  • Hansen 3000, 4000, 5000 and 6000

Construction

  • Machined components are manufactured using solid bar stock.
  • Stainless steel balls, retaining rings and springs maximize corrosion resistance and extend service life.
  • Nitrile (Nitrile Rubber) seals are standard
  • Steel componentry is plated using ROHS Compliant Trivalent Chrome.
  • Steel tubular valve

How It Works

  • To disconnect, begin by holding the hose on the nipple side with three of your fingers, leaving your thumb and index finger free.
  • Grab the sleeve with your thumb and index finger and begin to pull the sleeve towards the palm of your hand.
  • After pulling the sleeve, the nipple will move out of the coupler slightly. Continue to hold the hose and coupler sleeve until all air is fully exhausted.
  • After the line is fully exhausted, you are able to safely separate the nipple from the coupler.

Safety Notes

  • It is important to be safe when installing quick disconnect couplings into a pneumatic circuit. Never install a pneumatic coupling directly into an air tool, use a piece of hose that is at least 18" long, between the tool and the coupling, to prevent damage to the coupling. To protect the operator, safety devices, such as a safety check valve and safety cable should be installed in case there is a hose or coupling failure.
  • Operating pressure for couplings utilizing hose barb connections may be dramatically reduced to that of the hose rating and/or hose end connection combination. Consult hose manufacturer's catalog for hose end connection ratings. If in doubt, test under controlled conditions for suitability to application.
  • Dixon cannot assume liability for misapplication of production resulting in equipment down-time, lost production, and/or personal injury including death.

Specifications

  • Rated pressure for connected Brass Coupler & Brass Plug: 300 PSI (20 bar) Maximum Working and 16,000 PSI (1,100 bar) Burst
  • Rated pressure for connected Brass Coupler & Steel Plug: 500 PSI (35 bar) Maximum Working and 16,000 PSI (1,100 bar) Burst
WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.